info@thermodicht.eu| +31 50 260 50 50

View our impression? Click here!
  • Home
  • BlowerDoor
    • The BlowerDoor test
    • Residential and commercial buildings
    • Passive house standard
    • Hospitals
    • Data centers & computer rooms
    • Cold stores
    • Thatched roof constructions
    • Leak Detection
    • BlowerDoor XL
    • Rental BlowerDoor
    • Sales BlowerDoor
  • Thermography
    • About Thermography
    • Electricity research
    • Control heating
    • Inspection and leak detection
    • Rental Fluke TiR1
  • Sound
    • Sound measurements
    • Airborne sound
    • Contact Sound
    • Sound insulation of façade and roof
    • Installation Sound
    • Spatial Acoustics
  • Ventilation
    • Properly ventilate
    • Flow Measurements
    • Indoor Air Quality
  • Building physics
    • Building physics calculations
    • EP calculations
    • PHPP calculations
    • Ventilation Calculations
    • Energy Saving Advice
    • Thermal bridge calculations
    • Daylight Calculations
  • Knowledge
    • Information durability
    • STABU specification texts
    • Documentation
    • Publications
    • SKH-PUBLICATION 13-01 Airtightness Measurements (NL)
    • Platform airtight renovate
    • Passive building
    • Balanced ventilation
    • Mechanical extraction
    • BREEAM HEA 13
    • BREEAM ENE 26
    • Frequently Asked Questions
    • Sitemap
  • About us
    • Mission
    • Contact
    • News
    • Jobs
    • Partners
    • Linkpartners
    • Certification
    • BlowerDoor film
    • Thermodicht on video
    • Example report
    • Algemene voorwaarden
youtube

Inspection and leak detection

Cracks and crevices

Monitoring during and after completion of the thermal insulation and air exchange through cracks and crevices (infiltration) are determining factors for the energy use of a building in the use phase. With the increasing insulation of the building envelope increasing the negative impact of any imperfections far. Too small a thermal quality of the building shell can include fungal attack have the effect on the inside of the structure. Air leaks in the building envelope can cause draft problems, building damage, (eg by internal condensation), and a moist indoor environment (eg air leaks in the ground floor).

Pipes

Not every damp wall is caused by a ruptured pipe. Rising damp or penetrating water due to the poor implementation of rain and drain flushing water can cause damp walls. Moisture damage can also be caused by clogged pipes or insufficient flow. It is important that the cause of rising damp or water precipitation at the earliest possible stage is found with a thermal imager. This will prevent the damage will further expand.

Thermal bridges

Thermal bridges, connecting the outer surface (wall, roof or floor) of a house / building, are energy wasters. In places of thermal bridges, moisture may condense from the air. As a result, there develops fungal growth on these sites and runs the health of residents / users at greater risk. Thermographic / infrared images provide the necessary information to prevent mold or detect, even in hidden corners and niches of a house / building.

  • Building thermography
  • Electricity research
  • Control heating
  • Inspection and leak detection
  • Rental Fluke TiR1

Reference projects

  • Waterland Hospital in Purmerend
    Waterland Hospital in Purmerend
  • University Medical Center Utrecht
    University Medical Center Utrecht
  • newAmsterdam building Amsterdam Southeast
    newAmsterdam building Amsterdam Southeast
  • Erasmus MC hospital in Rotterdam
    Erasmus MC hospital in Rotterdam
  • Blowerdoortest woning St. Nicolaasga https://t.co/jCQ4sH7SwW via @KramersBB over a year ago
  • Super goed gedaan, erg leuk om zulke resultaten te meten ! https://t.co/Y5zZbudb5E over a year ago
  • Testen van Ellen- tochtprofielen voor Elton BV https://t.co/fYHxe9NEc0 over a year ago
  • RT @blowertechnic: Simultane Blowerdoor meting van 7 woningen te Nederland! Samen met collega Herman Bos van Thermodicht. Wat een leuke sam… over a year ago
  • Sponsor van Het BeterBoek Waterland Ziekenhuis Purmerend https://t.co/tQ2A8LRMh7 over a year ago

Address

Thermodicht
Waardeel 5
9756 AP Glimmen
E info@thermodicht.eu
T +31 50 260 50 50

KvK Groningen 01143872
Btw nr. NL098072675B01

Interesting

  • Noise nuisance
  • BlowerDoor Netherlands
  • Linkpartners
  • Webshop BlowerDoor
  • Cleanrooms
  • Jobs

Sociale media

  • facebook
  • googleplus
  • linkedin
  • twitter
  • youtube

Laatste tweets

"Blowerdoortest woning St. Nicolaasga https://t.co/jCQ4sH7SwW via @KramersBB"
© 2010 - 2019 Thermodicht. All Rights Reserved - Website by Jb-WebDesign.nl
We work according to the standards.